These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: A Nomogram of MRI Features to Assess Muscle Invasion in VI-RADS 2 Tumors With Stalk.
    Author: Cai L, Yu R, Liu P, Zhuang J, Li K, Wu Q, Sun X, Liu Y, Zhou M, Cao Q, Li P, Yang X, Lu Q.
    Journal: J Magn Reson Imaging; 2024 Apr; 59(4):1179-1190. PubMed ID: 37602726.
    Abstract:
    BACKGROUND: Vesical Imaging-Reporting and Data System (VI-RADS) is widely used to assess the muscle-invasive status of bladder cancer. However, the current classification efficacy of VI-RASD 2 tumors of stalk is unsatisfactory. PURPOSE: To develop a nomogram to assess muscle-invasive bladder cancer (MIBC) in VI-RADS 2 tumors with stalk. STUDY TYPE: Retrospective. POPULATION: A total of 186 patients (age: 67.8 ± 12.7 years) with 15.1% females, divided randomly into a training cohort (N = 130) and validation cohort (N = 56). FIELD STRENGTH/SEQUENCE: 3-T, T2-weighted imaging (turbo spin-echo), diffusion-weighted imaging (breathing-free spin-echo), and dynamic contrast-enhanced imaging (gradient-echo). ASSESSMENT: Twenty-one MRI features of tumors and stalks were developed from training cohort. The mean apparent diffusion coefficient (ADC) values of the tumor, stalk, and psoas muscles were calculated from the three circular regions of interest. The normalized T value = mean ADC tumor mean ADC muscle . The normalized ST value = mean ADC stalk mean ADC tumor . Three readers assessed the morphology of tumors and stalks. STATISTICAL TESTS: The final features of nomogram were selected by univariable logistic and the least absolute shrinkage and selection operator (LASSO) regression. The performance of the nomogram was assessed by the receiver operating characteristic (ROC) curve, calibration, and decision curve analysis. RESULTS: In VI-RADS 2 tumors with stalk, tumor size over 3 cm, increased stalk width, stalk morphology, decreased normalized T value, and increased normalized ST value were selected as the risk factors for MIBC. The AUC, accuracy, sensitivity, and specificity of the nomogram to assess MIBC were 0.969 (95% CI: 0.941-0.997), 92.3%, 94.1%, and 92.0% in training cohort and 0.940 (95% CI: 0.859-1.000), 89.3%, 75.0%, and 91.7% in validation cohort. DATA CONCLUSION: This study constructed a nomogram for preoperative assessment of MIBC and modifying the current VI-RADS. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 2.
    [Abstract] [Full Text] [Related] [New Search]