These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Clinical and radiographic long-term outcomes of hemiarthroplasty for complex proximal humeral fractures.
    Author: Hasler A, Ker A, Grubhofer F, El Nashar R, Ernstbrunner L, Gerber C, Wieser K.
    Journal: J Shoulder Elbow Surg; 2024 Mar; 33(3):698-706. PubMed ID: 37611843.
    Abstract:
    BACKGROUND: Hemiarthroplasty (HA) is a treatment option for complex proximal humeral fractures not suitable for conservative treatment or open reduction-internal fixation. Long-term outcomes using a large-metaphyseal volume prosthesis in the management of proximal humeral fractures have not been reported thus far. METHODS: Between 2006 and 2010, 41 patients with proximal humeral fractures were treated with HA at our institution (average age, 62 years; age range, 38-85 years). Nine patients underwent revision surgery, 3 were lost to follow-up, and 7 died unrelated to the index surgical procedure. Twenty-two patients were reviewed clinically and radiographically after a mean period of 10.4 years (range, 9-13 years). RESULTS: Of the 9 HA failures, 7 occurred within the first 2 postoperative years: 2 patients had infections and 5 had greater tuberosity nonunions or malunions. The other 2 patients underwent revision for rotator cuff deficiency >5 years after initial surgery. Among the patients available for final follow-up, the implant survival rate was 71% (22 of 31 patients). At final follow-up, these patients showed a mean relative Constant score of 76% (range, 49%-96%), mean active elevation of 116° (range, 60°-170°), and mean external rotation of 28° (range, 0°-55°). The majority had good or excellent internal rotation, with internal rotation to the 12th thoracic vertebra in 13 patients (59%) and to the eighth thoracic vertebra in 7 (31%). The mean Subjective Shoulder Value was 76% (range, 40%-100%). Clinical outcomes did not significantly deteriorate over a period of 10 years, except for flexion (P < .001) and internal rotation (P = .002). On analysis of greater tuberosity healing, 1 patient had a nonunion and 10 patients (45%) had a malunion, whereas the greater tuberosity had healed in an anatomic position in 12 patients (55%). Patients with a displaced malunion of the greater tuberosity did not have inferior clinical results at last follow-up. Only 2 patients showed glenoid erosion, and in no patients could stem loosening be identified at final follow-up. CONCLUSION: The revision rate following large-metaphyseal volume HA to treat a proximal humeral fracture was 29% after 10 years postoperatively, with failure within 2 years largely related to greater tuberosity nonunion or malunion and failure later related to rotator cuff insufficiency. Patients with a retained implant showed good clinical and radiographic long-term results, without relevant deterioration over time even when the greater tuberosity healed in a nonanatomic position.
    [Abstract] [Full Text] [Related] [New Search]