These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Homochiral Metallacycle Used as a Stationary Phase for Capillary Gas Chromatographic Separation of Chiral and Achiral Compounds. Author: Huang B, Li K, Ma QY, Xiang TX, Liang RX, Gong YN, Wang BJ, Zhang JH, Xie SM, Yuan LM. Journal: Anal Chem; 2023 Sep 05; 95(35):13289-13296. PubMed ID: 37615071. Abstract: Metallacycles are a novel class of supramolecular materials with circular structures, internal cavities, and abundant host-guest chemical properties that have exhibited good application prospects in many fields. However, to the best of our knowledge, no research on the use of metallacycles as stationary phases for gas chromatographic (GC) separations has been published yet. In this work, we report for the first time the use of a homochiral metallacycle, [ZnCl2L]2, as a stationary phase for GC separations. [ZnCl2L]2 was synthesized by reaction of (S)-(1-isonicotinoylpyrrolidin-2-yl)methyl-isonicotinate (L) with ZnCl2via coordination-driven self-assembly. The [ZnCl2L]2-coated column displayed an excellent separation performance not only of organic isomers but also of racemic compounds. Sixteen racemates (including alcohols, esters, amino acid derivatives, ethers, organic acids, and epoxides) and 21 isomeric compounds (including positional, structural, and cis/trans-isomers) were well separated on the [ZnCl2L]2-coated column. Impressively, some racemates were resolved with high resolution values (Rs), including 1,2-butanediol diacetate (Rs = 25.86), ethyl 3-hydroxybutyrate (Rs = 20.97), 1,3-butanediol diacetate (Rs = 18.09), and threonine derivative (Rs = 18.61). Compared with the commercial β-DEX 120 column for separation of the tested racemates, the [ZnCl2L]2-coated column exhibited good enantioseparation complementarity, enabling separation of some racemates that could not be separated, or were not well resolved, by the β-DEX 120 column. In addition, many organic mixtures, such as n-alkanes, alkylbenzenes, n-alcohols, and a Grob test mixture, were also well separated on the [ZnCl2L]2-coated column. The column also has good reproducibility and thermal stability on separation. This work not only reveals the great potential of metallacycles for GC separations but also opens up a new application of metallacycles in separation science.[Abstract] [Full Text] [Related] [New Search]