These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Acquired tracheo-oesophageal fistula after ingestion of a mercury button-battery. Author: Van Asperen PP, Seeto I, Cass DT. Journal: Med J Aust; 1986 Oct 20; 145(8):412-5. PubMed ID: 3762480. Abstract: We report the case of a nine-month-old girl with acquired oesophageal stricture and tracheo-oesophageal fistula after the ingestion of a mercury button-battery. In any child with suspected button-battery ingestion an x-ray examination should be carried out to exclude oesophageal impaction which necessitates immediate removal of the battery, as tissue necrosis may occur within hours.[Abstract] [Full Text] [Related] [New Search]