These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Cardiopulmonary Performance Among Heart Failure Patients Before and After Left Ventricular Assist Device Implantation. Author: Buchanan C, Buchanan C, Riordan M, Byrd J, Schulte M, Kohrt WM, Ambardekar AV, Allen LA, Wolfel G, Lawley J, Levine BD, Cornwell WK. Journal: JACC Heart Fail; 2024 Jan; 12(1):117-129. PubMed ID: 37632493. Abstract: BACKGROUND: Patients with heart failure with reduced ejection fraction (HFrEF) have persistent impairments in functional capacity after continuous-flow left ventricular assist device (CF-LVAD) implantation. OBJECTIVES: This study aims to characterize longitudinal changes in exercise hemodynamics and functional capacity among patients with HFrEF before and after CF-LVAD implantation. METHODS: Ten patients underwent 3 invasive cardiopulmonary exercise tests on upright cycle ergometry with pulmonary artery catheterization: 1) Visit 1 before CF-LVAD implantation; 2) Visit 2 after device implantation with CF-LVAD pump speed held constant at baseline speed; and 3) Visit 3 with increases in pump speed during exercise (median: 1,050 rpm [IQR: 750-1,150 rpm] and 220 rpm [IQR: 120-220 rpm] for HeartMate 3 and HeartWare VAD, respectively). Hemodynamics and direct Fick cardiac output were monitored using pulmonary artery catheterization. Gas exchange metrics were determined using indirect calorimetry. RESULTS: Maximal oxygen uptake (Visits 1, 2, and 3: 10.8 ± 2.5 mL/kg/min, 10.7 ± 2.2 mL/kg/min, and 11.5 ± 1.7 mL/kg/min; P = 0.92) did not improve after device implantation. Mean pulmonary arterial and pulmonary capillary wedge pressures increased significantly during submaximal and peak exercise on preimplantation testing (P < 0.01 for rest vs peak exercise) and remained elevated, with minimal change on Visits 2 and 3 regardless of whether pump speed was fixed or increased. CONCLUSIONS: Among patients with HFrEF, cardiovascular hemodynamics and exercise capacity were similar after CF-LVAD implantation, regardless of whether patients exercised at fixed or adjusted pump speeds during exercise. Further research is needed to determine methods by which LVADs may alleviate the HFrEF syndrome after device implantation. (Effect of mechanIcal circulatoRy support ON exercise capacity aMong pAtieNts with heart failure [IRONMAN]; NCT03078972).[Abstract] [Full Text] [Related] [New Search]