These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Liquid chromatographic determination of bendiocarb in technical materials and wettable powder formulations: collaborative study. Author: Carter PL, Overton KC. Journal: J Assoc Off Anal Chem; 1986; 69(5):908-11. PubMed ID: 3771466. Abstract: A liquid chromatographic method for determination of bendiocarb in technical materials and wettable powders was tested by 12 collaborators. Bendiocarb is dissolved in acetonitrile containing 0.1% propiophenone as internal standard. This solution is analyzed on a liquid chromatograph utilizing a reverse phase (C18) column. The compound is detected at 254 nm and peak area is used for quantitation. The 3 different materials studied contained 20, 80, and nominally 100% bendiocarb. Each was examined in duplicate to provide the necessary matched pairs. Collaborators approved of the ease and simplicity of the method and, in particular, the way the method can be applied to automatic injection assemblies. The statistical data show acceptable precision of the method: Reproducibility coefficients of variation were 20% material, 2.04%; 80% material, 1.02%; and nominal 100% material (technical product), 0.64%. The method has been adopted official first action.[Abstract] [Full Text] [Related] [New Search]