  • Title: Validation of an LC-MS/MS assay for rapid and simultaneous quantification of 21 kinase inhibitors in human plasma and serum for therapeutic drug monitoring.
    Author: Al Shirity ZN, Westra N, Hateren KV, Munnink THO, Kosterink JGW, Mian P, Hooge MNL, Touw DJ, Gareb B.
    Journal: J Chromatogr B Analyt Technol Biomed Life Sci; 2023 Sep 01; 1229():123872. PubMed ID: 37716342.
    Abstract:
    Kinase inhibitors have revolutionized cancer treatment in the past 25 years and currently form the cornerstone of many treatments. Due to the increasing evidence for therapeutic drug monitoring (TDM) of kinase inhibitors, the need is growing for new assays to rapidly evaluate kinase inhibitor plasma concentrations. In this study, we developed an LC-MS/MS assay for the rapid and simultaneous quantification of 21 kinase inhibitors. First, a literature search was conducted to ensure that the linear ranges of the analytes were in line with the reported therapeutic windows and/or TDM reference values. Subsequently, the assay was validated according to FDA and EMA guidelines for linearity, selectivity, carry-over, accuracy, precision, dilution integrity, matrix effect, recovery, and stability. The assay was fast, with a short run-time of 2 min per sample. Sample pre-treatment consisted of protein precipitation with methanol enriched with stable isotope-labeled internal standards (SIL-IS), and the mixture was vortexed and centrifuged before sample injection. Separation was achieved using a C18 column (3 μm,50 × 2.1 mm) with a gradient of two mobile phases (ammonium formate buffer pH 3.5 and acetonitrile). Analyte detection was conducted in positive ionization mode using selected reaction monitoring. The assay was accurate and precise in plasma as well as in serum. Extraction recovery ranged between 95.0% and 106.0%, and the matrix effect was 95.7%-105.2%. The stability of the analytes varied at room temperature and in refrigerated conditions. However, all drugs were found to be stable for 7 days in the autosampler. The clinical applicability of the analytical method (486 analyzed samples between 1 July 2022-1 July 2023) as well as external quality control testing results were evaluated. Taken together, the results demonstrate that the analytical method was validated and applicable for routine analyses in clinical practice.
    [Abstract] [Full Text] [Related] [New Search]