These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Vibration from riveting tools in the frequency range 6 Hz-10 MHz and Raynaud's phenomenon. Author: Dandanell R, Engström K. Journal: Scand J Work Environ Health; 1986 Aug; 12(4 Spec No):338-42. PubMed ID: 3775319. Abstract: The vibration characteristics of hand-held riveting hammers and bucking bars used in the aircraft industry were measured and recorded for frequencies from 6 Hz to 10 MHz. Three different measuring systems had to be used. Up to about 1 kHz a displacement transducer was used, up to about 50 kHz a piezoelectric accelerometer was used, and in the megahertz region an ultrasonic probe was used. The signals were analyzed according to the guidelines of the International Organization for Standardization (ISO/DIS 5349), and also according to methods common in environmental engineering. The weighted acceleration according to ISO/DIS 5349 was between 10 and 11 m/s2 for typical riveting tools. Very high acceleration values were obtained for frequencies above those specified in ISO/DIS 5349. In a group of 288 riveters, about 50% showed symptoms indicating Raynaud's phenomenon after about 10 years of work, although the daily exposure of riveting tools was about 1 min/d. The investigation showed that special precautions must be taken to measure the acceleration of percussion tools and that the risk criteria in ISO/DIS 5349 do not cover all the risks connected with percussion tools.[Abstract] [Full Text] [Related] [New Search]