These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: [Hemolytic anemia as a result of hemodynamically-insignificant paravalvular dehiscence of St. Jude-Medical aortic valve prosthesis]. Author: Horstkotte D, Pippert H, Körfer R, Bircks W, Loogen F. Journal: Z Kardiol; 1986 Aug; 75(8):502-4. PubMed ID: 3776290. Abstract: The course of a patient with aortic valve replacement is reported in whom increased intravascular hemolysis and auscultatory findings were suspicious of paravalvular dehiscence although other non-invasive examinations did not reveal pathological findings. Heart catheterization showed nearly normal pressures and angiocardiography minimal diastolic transaortic regurgitation. Nevertheless the patient had to be reoperated due to severe hemolytic anemia. Successful closure of the periprosthetic leakage resulted in prompt normalisation of laboratory findings of hemolysis.[Abstract] [Full Text] [Related] [New Search]