These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Improved Value of Multiplexed Sensitivity Encoding DWI with Reversed Polarity Gradients in Diagnosing Prostate Cancer: A Comparison Study with Single-Shot DWI and MUSE DWI.
    Author: Zhao W, Ju S, Yang H, Wang Q, Fang L, Pylypenko D, Wang W.
    Journal: Acad Radiol; 2024 Mar; 31(3):909-920. PubMed ID: 37778902.
    Abstract:
    RATIONALE AND OBJECTIVES: This study aimed to investigate the value of multiplexed sensitivity encoding with reversed polarity gradients in improving the quality of diffusion-weighted imaging (DWI) images of the prostate and the diagnostic efficacy of prostate cancer. MATERIALS AND METHODS: Seventy-three patients with prostate disease underwent multiplexed sensitivity encoding with reversed polarity gradients (RPG-MUSE), multiplexed sensitivity encoding (MUSE), and single-shot echo-planar imaging (ssEPI) DWI. Three radiologists performed a qualitative image analysis of the three DWI sequences. Qualitative image analysis included artifact minimization, anatomical detail, and sharpness of prostate edges. Two radiologists measured the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), geometric distortion rate, and the apparent diffusion coefficient (ADC) values of the prostate disease tissue. Two radiologists jointly performed Prostate Imaging Reporting and Data System scoring of prostate lesions and compared the diagnostic efficacy of the three DWI sequences for prostate cancer. RESULTS: There was good agreement among radiologists in the evaluation and measurement of the three DWI sequence images (intraclass correlation coefficient >0.75, P < 0.05). The RPG-MUSE DWI images were rated higher than those of MUSE and ssEPI in terms of artifact minimization, anatomical details, and sharpness of prostate edges (P < 0.05). The SNR and CNR of the RPG-MUSE DWI images were higher than those of MUSE and ssEPI (P < 0.05), and the geometric distortion rate was lower than that of the other two sequences (P < 0.05). There were no statistical differences in ADC values between the three DWI sequences (P > 0.05). The diagnostic efficacy of RPG-MUSE and MUSE DWI was higher than that of ssEPI (P < 0.017). CONCLUSION: RPG-MUSE can reduce the artifacts and geometric distortion in DWI images of the prostate, improve the SNR and CNR of the images, improve the clarity of anatomical details and boundaries without affecting the measurement of ADC values, has the potential to improve the diagnostic efficacy of prostate lesions, and facilitates the clear display and accurate assessment of prostate lesions.
    [Abstract] [Full Text] [Related] [New Search]