These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Simultaneous analysis of carcinogenic N-nitrosamine impurities in metformin tablets using on-line in-tube solid-phase microextraction coupled with liquid chromatography-tandem mass spectrometry. Author: Ishizaki A, Ozawa K, Kataoka H. Journal: J Chromatogr A; 2023 Nov 08; 1710():464416. PubMed ID: 37804578. Abstract: Contamination of active pharmaceutical ingredients (APIs) and pharmaceutical preparations with carcinogenic N-nitrosamines has led to recalls of these products and supply shortages to patients. The present study describes the development of a highly sensitive method for simultaneous analysis of seven N-nitrosamines using on-line in-tube solid-phase microextraction (IT-SPME) coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS) to determine their actual contamination in metformin tablets. Using a Carboxen 1006 PLOT capillary as the extraction device for IT-SPME, these compounds were efficiently extracted and concentrated 6‒24-fold by subjecting 40 µL of sample to 25 repeated draw/eject cycles at a rate of 0.2 mL/min. The seven N-nitrosamines were separated within 11 min by gradient elution with 0.1 % formic acid solution and acetonitrile as the mobile phase using a CAPCELL PAK C18 MGII column and detected by multiple reaction monitoring in positive ion mode. The calibration curve showed linearity in the range 0.2‒50 ng/mL and detection limits (S/N = 3) in the range 3‒112 pg/mL. The intra-day and inter-day precisions were less than 5.5 % and 7.0 % (n = 6), respectively, with accuracies ranging from 93‒117 %. Following ultrasonic extraction with water, centrifugation and filtration of the supernatant liquid through a membrane filter, the N-nitrosamine impurities in metformin tablets could be analyzed by IT-SPME/LC‒MS/MS. Their limits of quantification (S/N = 10) were 0.1‒5.1 pg/mg API and recoveries ranged from 87‒102 %. Analysis of eight metformin tablets from eight manufacturers showed that 5.8‒7.5 pg/mg N-nitrosodimethylamine were present in three tablets, with no other N-nitrosamines detected in any of the eight tablets. This method may be useful in testing for N-nitrosamine impurities in pharmaceutical preparations.[Abstract] [Full Text] [Related] [New Search]