  • Title: Conventional drilling versus ultrasound and laser osteotomy in mandibular third molar surgery: A comparative study.
    Author: Blagova B, Krastev D, Malinova L.
    Journal: Lasers Surg Med; 2023 Dec; 55(10):862-870. PubMed ID: 37811576.
    Abstract:
    BACKGROUND: There are few research works with in-depth studies and direct simultaneous comparisons of the effects on tissue reactions and patients' recovery following in vivo conventional drilling, ultrasound- and laser-assisted osteotomy in humans. OBJECTIVE: The current study aims to compare bone cutting duration, pain, swelling, and trismus in patients following surgical mandible third molar extraction by bone removal using three different osteotomes-a conventional rotary device, an ultrasonic unit, and an Er:YAG laser. METHODS: A prospective, randomized three-group comparative clinical trial was performed. As an experimental setting for the study, аn open mandible third molar surgery was chosen because osteotomy is included in its protocol. Patients were divided into three groups according to the used device for bone removal. Bone cutting time intraoperatively, facial swelling, trismus, and pain on the first, second, and third postoperative days were assessed. The statistical analyses were performed using the SPSS v. 17.0-Kolmogorov-Smirnov test, one-way ANOVA, Student's t-test, Mann-Whitney test, and χ2  test. Statistical results were considered significant at p < 0.05 (confidence interval of difference, 95% CI). RESULTS: Eighty patients (34 males and 46 females with an average age of 25.18 years) were included in the study. The average time for bone removal by the conventional low-speed device (4.95 min), by the ultrasonic unit (5.13 min), and by the Er:YAG laser (9.00 min) differed significantly (p = 0.001). The mean postoperative facial swelling showed a marked difference between the groups (p < 0.05), in favor of the laser and piezo groups. The osteotome proved to influence pain intensity not only immediately after surgery (p = 0.002), but also during the followed-up period (p = 0.001), again in favor of the two above-mentioned groups. No association was found between trismus and the osteotome used by the followed-up patients (p > 0.05). CONCLUSION: Bone-cutting mechanism and the biological influence of the laser beam and ultrasound on living tissues proved to be favorable factors for patients' pain levels and tissue swelling postoperatively independent of the longer osteotomy duration compared to conventional drilling.
    [Abstract] [Full Text] [Related] [New Search]