These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Bone bonding behavior of three kinds of apatite containing glass ceramics. Author: Kitsugi T, Yamamuro T, Nakamura T, Higashi S, Kakutani Y, Hyakuna K, Ito S, Kokubo T, Takagi M, Shibuya T. Journal: J Biomed Mater Res; 1986; 20(9):1295-307. PubMed ID: 3782183. Abstract: We have produced three kinds of apatite-containing glass ceramics of the same chemical composition: MgO (4.6), CaO (44.9), SiO2 (34.2), P2O5 (16.3), CaF2 (0.5) (in weight ratio). They contain different crystal combinations and have different mechanical properties. The first glass ceramic (A-GC) was prepared by heating a glass plate to 870 degrees C. It contains only oxy- and fluoroapatite (35 wt%). The second glass ceramic (A-W-GC), and the third (A-W-CP-GC), were prepared by heating glass powder compacts to 1050 degrees C and 1200 degrees C, respectively. A-W-GC contains oxyapatite and fluoroapatite (Ca10(PO4)6(O,F2] (35 wt%) and beta-wollastonite (40 wt%). A-W-CP-GC contains oxyapatite and fluoroapatite (20 wt%), beta-wollastonite (CaO X SiO2) (55 wt%), and beta-whitlockite (3CaO X P2O5) (15 wt%). The bending strengths of A-GC, A-W-GC, and A-W-CP-GC were 88MPa, 178MPa, and 213MPa, respectively, in air. Rectangular ceramic plates (15mm X 10mm X 2mm) were implanted into a rabbit tibia. Ten and 25 weeks after implantation, the segment of tibia with implant was excised for examination. The segment was held by a special jig and the traction breaking load (failure load) was measured by an autograph. A-GC showed a lower load than A-W-GC and A-W-CP-GC. The loads for A-W-GC and A-W-CP-GC were almost equal. The failure loads did not change significantly between 10 and 25 weeks for any of the materials. The interface was examined by Giemsa surface staining, contact micro-radiography, and SEM-EPMA. Giemsa surface staining and CMR revealed direct bonding between the materials and the bone for all the three materials. SEM-EPMA showed that Si and Mg content decreased, Ca content did not change, and P content increased at the reaction zone between all three glass ceramics and bone. This was observed at 10 weeks, as well as at 25 weeks, after implantation. The reaction zone was narrowest with A-GC, wider with A-W-GC, and widest with A-W-CP-GC.[Abstract] [Full Text] [Related] [New Search]