These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: 6-mm shunt transjugular intrahepatic portosystemic shunt in patients with severe liver atrophy and variceal bleeding. Author: Yan H, Xiang Z, Zhao C, Luo S, Liu H, Li M, Huang M. Journal: Eur Radiol; 2024 Jul; 34(7):4697-4707. PubMed ID: 38006453. Abstract: OBJECTIVES: We proposed a strategy for the creation of a 6-mm transjugular intrahepatic portosystemic shunt (TIPS) and to assess its effectiveness compared to a conventional 8-mm shunt for TIPS-induced hepatic encephalopathy (HE). METHODS: Patients were reviewed retrospectively using propensity score matching (1:1) and divided into 6-mm and 8-mm shunt groups based on shunt diameter. The stent patency, HE incidence, and rebleeding rate between the two groups were then compared. RESULTS: From January 2018 to June 2021, both 6-mm shunt group and 8-mm shunt group included 58 patients. The 6-mm shunt group had significantly smaller liver volumes (879.3 ± 237.1 vs. 1008.8 ± 293.0; p = 0.010), and the median stent patency times were 30.7 and 33.8 months in the 6-mm and 8-mm groups, respectively (p = 0.124). No statistically significant difference was found between the two groups in the 1-year (8.6% vs. 3.4%; p = 0.242) and 2-year (17.2% vs. 12.1%; p = 0.242) rebleeding rates. The 1-year cumulative incidences of overt HE were 12.1% and 27.6% in the 6-mm and 8-mm groups, respectively (p = 0.040), and the 2-year cumulative overt HE incidences in these groups were 19.0% and 36.2%, respectively (p = 0.038). Notably, patients with a 6-mm shunt also experienced less hepatic impairment. CONCLUSIONS: For patients with variceal bleeding and a small liver volume, the 6-mm shunt significantly reduced the incidence of overt HE, protected perioperative liver function, and did not affect stent patency or rebleeding rate. CLINICAL RELEVANCE STATEMENT: For patients with variceal bleeding with small liver volume, the 6-mm transjugular intrahepatic portosystemic shunt (TIPS) significantly reduced the incidence of overt hepatic encephalopathy after TIPS, protected perioperative liver function, and did not affect stent patency and rebleeding rate. KEY POINTS: • A strategy for the creation of a 6-mm transjugular intrahepatic portosystemic shunt for patients with variceal bleeding and a small liver volume was proposed. • The 6-mm transjugular intrahepatic portosystemic shunt significantly reduced the incidence of overt hepatic encephalopathy. • The 6-mm transjugular intrahepatic portosystemic shunt did not affect stent patency or rebleeding rate.[Abstract] [Full Text] [Related] [New Search]