These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Transarterial Embolization of Simple Pulmonary Arteriovenous Malformations: Long-Term Outcomes of 0.018-Inch Coils versus Vascular Plugs. Author: Botsford A, Tradi F, Loubet A, Tantawi S, Soulez G, Giroux MF, Faughnan ME, Gauthier A, Perreault P, Bouchard L, Holderbaum do Amaral R, Chartrand-Lefebvre C, Therasse E. Journal: J Vasc Interv Radiol; 2024 Mar; 35(3):349-360. PubMed ID: 38013007. Abstract: PURPOSE: To compare the safety, effectiveness, and persistence rates of 0.018-inch coils with those of Amplatzer vascular plugs (AVPs; Abbott Vascular, Abbott Park, Illinois) for the treatment of pulmonary arteriovenous malformations (PAVMs) in response to a growing concern that 0.018-inch coil embolization would increase the long-term persistence rate. MATERIALS AND METHODS: This is a retrospective, single-center study of a database (2002-2020) of 633 PAVM embolizations. Complex PAVMs and those not embolized with 0.018-inch coils or plugs were excluded. PAVM embolization material was classified into 4 groups: (a) 0.018-inch nonfibered coils (NFCs), (b) 0.018-inch fibered coils (FCs), (c) NFCs and FCs, or (d) plugs. Persistence was defined as flow through the PAVM on digital subtraction angiography (DSA) or as <30% diameter reduction of the aneurysmal sac on unenhanced computed tomography (CT). Kaplan-Meier analysis and Cox regression were used to assess PAVM's persistence-free survival. RESULTS: A total of 312 PAVM embolizations with NFCs (43 PAVMs), FCs (127 PAVMs), NFCs and FCs (12 PAVMs), or plugs (130 PAVMs) in 109 patients (28% men; mean age = 49 years) were included. All PAVM embolizations were technically successful without any major adverse events. PAVM persistence-free survival rates at 10 years' follow-up were 40.8% versus 44.7% in the NFC and FC groups (P = .22) and 47.3% versus 81.0% in the 0.018-inch coil (NFC or FC) and plug groups (P < .0001), respectively. There were 0.43 (79/182) and 0.08 (10/130) re-embolization procedures per PAVM in the 0.018-inch coil and plug groups, respectively (P < .001). CONCLUSIONS: PAVM embolization with 0.018-inch coils was safe, but persistence rate with PAVM embolization was significantly higher than that with plugs, with no significant differences between FCs and NFCs.[Abstract] [Full Text] [Related] [New Search]