These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: [Investigation of the Usefulness of Monte Carlo Simulation in Electron Beam Therapy Using Body Surface Lead Cutout]. Author: Ono N. Journal: Nihon Hoshasen Gijutsu Gakkai Zasshi; 2024 Feb 20; 80(2):175-187. PubMed ID: 38030241. Abstract: PURPOSE: The purpose of this study was to understand the PDD and OAR during electron beam therapy using lead cutout on the body surface. METHODS: The Monte Carlo code PHITS version 3.24 was used to simulate PDD and OAR. The simulation results were compared with actual measurements using a silicon diode detector to evaluate the validity of the simulation results. RESULTS: The simulated PDD and OAR parameters of the linac agreed with the measured values within 2 mm. When the lead cutout on the body surface was used, all parameters except for R100 agreed with the measured values within 2 mm. The cutout sizes of the broad-beam square irradiation fields were 3 cm for 6 MeV, 5 cm for 12 MeV, and 8 cm for 18 MeV when the lead cutout on the body surface was used. CONCLUSION: The Monte Carlo simulation was useful for understanding the PDD and OAR of the lead cutout irradiation fields, which are difficult to measure.[Abstract] [Full Text] [Related] [New Search]