These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Nebulization versus metered-dose inhaler and spacer in bronchodilator responsiveness testing: a retrospective study. Author: Lu R, Li Y, Hu C, Pan P, Zhao Q, He R. Journal: Ther Adv Respir Dis; 2023; 17():17534666231214134. PubMed ID: 38073272. Abstract: BACKGROUND: The recommended delivery mode for bronchodilators in bronchodilator responsiveness (BDR) testing remains controversial. OBJECTIVE: To compare the efficacy of salbutamol administration using a nebulizer versus a metered-dose inhaler (MDI) with spacer in BDR testing. DESIGN: A retrospective study. METHODS: This study examined the data of patients with chronic obstructive pulmonary disease who completed BDR testing between 1 December 2021 and 30 June 2022, at Xiangya Hospital, Central South University. After administering 400 μg of salbutamol through an MDI with spacer or 2.5 mg using a nebulizer, the changes in forced expiratory volume in one second (FEV1) and forced vital capacity (FVC) were analyzed in patients with moderate-to-very severe spirometric abnormalities [pre-bronchodilator FEV1 percentage predicted values (FEV1%pred) ⩽59%]. Significant responsiveness was assessed as >12% and >200 mL improvement in FEV1 and/or FVC or >10% increase in FEV1%pred or FVC percentage predicted values (FVC%pred) from pre- to post-bronchodilator administration. RESULTS: Of the enrolled 894 patients, 83.2% were male (median age, 63 years). After propensity score matching, 240 pairs of patients were selected. The increment in FEV1 and increased FEV1 relative to the predicted value (ΔFEV1%pred) were significantly higher in patients <65 years and those with severe spirometric abnormalities in the nebulization group than patients in the MDI group (all p < 0.05). Compared with MDI with spacer, patients who used nebulization had a 30 mL greater increase in ΔFEV1 (95% CI: 0.01-0.05, p = 0.004) and a 1.09% greater increase in ΔFEV1%pred (95% CI: 0.303-1.896, p = 0.007) from baseline. According to the > 12% and >200 mL increase criterion, the significant BDR rate with nebulization was 1.67 times higher than that with an MDI with spacer (OR = 1.67, 95% CI: 1.13-2.47, p = 0.009). CONCLUSION: Salbutamol delivered using a nebulizer may be preferable to an MDI with spacer in certain circumstances. Nebulization has the potential to increase responsiveness to salbutamol in BDR testing. Nebulization versus metered-dose inhaler and spacer in bronchodilator responsiveness testingBronchodilator responsiveness testing is commonly undertaken as an important part of spirometry testing to determine the degree of volume and airflow improvement after bronchodilator administration. BDR testing results may affect patients’ diagnosis and treatment. This study compared the effects of two delivery models (a metered dose inhaler (MDI) with spacer and nebulization) on responsiveness to bronchodilators and the results of bronchodilator responsiveness testing among patients with chronic obstructive pulmonary disease. We found that the increment in forced expiratory volume in one second were significantly higher in patients aged <65 years and in those with severe spirometric abnormalities in the nebulization group than in those in the MDI group. The study provides evidence that salbutamol delivered by a nebulizer is preferable to an MDI with spacer in patients <65 years and in those with severe spirometric abnormalities and could increase positive responsiveness to bronchodilators. The study will assist in clinical decision-making by selecting the appropriate dosing regimen for different patients.[Abstract] [Full Text] [Related] [New Search]