These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Fibreoptic bronchoscopy for tracheal and endobronchial intubation with a double-lumen tube.
    Author: Shulman MS, Brodsky JB, Levesque PR.
    Journal: Can J Anaesth; 1987 Mar; 34(2):172-3. PubMed ID: 3829304.
    Abstract:
    A 68-year-old patient was scheduled for a thoracotomy. A double-lumen endobronchial tube was requested by the surgeon to facilitate operating conditions. Initial attempts at intubation by conventional methods were unsuccessful. The proximal ends of a 37F double-lumen tube were then shortened and a 4-mm fibreoptic bronchoscope was passed through the bronchial lumen. The patient's larynx was easily visualized and the bronchoscope was passed into the trachea. The double lumen tube was then advanced over the bronchoscope and correctly positioned. Shortening a double-lumen tube allows the use of a fibreoptic bronchoscope to aid in tracheal intubation in a patient whose larynx is difficult to visualize by conventional methods.
    [Abstract] [Full Text] [Related] [New Search]