  • Title: Menstrual blood loss, haemoglobin and ferritin concentration of Beijing women wearing steel ring, VCu 200, and TCu 220c IUDs.
    Author: Gao J, Zeng S, Sun BL, Wu SC, Dong J, Cong J, Zhu XH, Fan HM, Han LH, Xie Z.
    Journal: Contraception; 1986 Dec; 34(6):559-71. PubMed ID: 3829674.
    Abstract:
    Menstrual blood loss (MBL), serum ferritin and whole blood cyanmethemoglobin were measured at pre- and 1, 3, 6, 12, 18 and 24th postinsertion cycles in 60 women wearing the Steel Ring, the Copper V (VCu 200) or the Copper T (TCu 220c). The MBL, incidence of menorrhagia and iron deficiency anemia were lower among users of the Steel Ring than among users of the Copper V and T. Anemia occurred later and the duration of menstruation was shorter with the Steel Ring than with the Copper T. There were no statistically significant differences between the Copper V and T. The effects of the Steel Ring, the Copper V (VCu 200), and the Copper T (TCu 220c) were compared in terms of menstrual blood loss, serum ferritin, the incidence of menorrhagia, and anemia before and after insertion to evaluate the safety of these IUDs and to determine if any of them are appropriate for longterm use in Chinese women. 60 healthy women, 20-39 years, with regular menstrual periods, normal pelvic examination, who had used no oral contraceptives (OCs) for more than 1 year were recruited. Those who previously had used an IUD or had an abortion or parturition were admitted after at least 3 normal menses. Each subject was instructed in the method for complete collection of menstrual blood for 1 entire menstrual period. Menstrual blood loss was measured by alkaline hematin photometry and a Stomacher Lab-blender was used for extraction. The insertions of the IUDs were uneventful. After insertion, the mean blood loss for each group at all intervals was significantly higher than that of preinsertion, especially in the 1st postinsertion cycle. Thereafter, blood loss remained high or gradually decreased, but it did not return to the preinsertion levels even at the 24th postinsertion cycle. The differences were still significant, especially for the T group. The mean increase 25.4 ml (55.8%) for the Ring group, 32.3 ml (56.8%) for the V group, and 39.9 ml (82.2%) for the T group. The highest blood loss for the Ring group was 154 ml, for the V group 290.9 ml, and for the T group 211 ml. The incidence of menorrhagia of all IUDs was significantly increased in the 1st postinsertion cycle. Except for the Ring group, the differences were still significant even in the 24th postinsertion cycle. The mean value of serum ferritin for the Ring group was significantly decreased at the 18 and 24th postinsertion cycles. For the V group, the mean value decreased significantly at the 6, 12, and 18th postinsertion cycles and was below the normal level (16 ng/ml). For the T group, the mean value decreased significantly at the 12th and 18th postinsertion cycles, but the difference was not significant at the 24th postinsertion cycle as compared with preinsertion in either the V or T groups. After insertion, the mean hemoglobin (Hb) concentrations were still above 12 gm/dl in each cycle, but the incidence of Hb less than 12 gm/dl, which was zero before insertion in all groups, for the Ring group was 12.5% and 6.2% at the 12 and 24th postinsertion cycles and for the V group, 10% at the 1st postinsertion cycle, then gradually increased to 21.1% at the 24th postinsertion cycle. Menstrual flow was significantly prolonged only in the T group. This study indicated that blood loss, incidence of menorrhagia, and iron deficiency anemia were lower among Steel Ring users than among VCu 200 and TCu 220c users.
    [Abstract] [Full Text] [Related] [New Search]