These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Measurement of Hp(10), Hp(3) and Hp(0.07) to medical staff in endoscopic retrograde cholangiopancreatography, using thermoluminescence dosimetry. Author: ZarifSanayei A, Sina S. Journal: Radiat Prot Dosimetry; 2024 Apr 04; 200(5):473-480. PubMed ID: 38324516. Abstract: Endoscopic retrograde cholangiopancreatography (ERCP) is widely used in the diagnosis and treatment of pancreatic and bile duct disorders. The procedure is performed under the guidance of fluoroscopy. This study aims to investigate the dose received by staff in the Endoscopy Department of AbuAli Sina Medicine and Organ Transplant Hospital in Shiraz. The dosimetry was performed using thermoluminescent dosemeters (TLD), type TLD-100. The values of Hp(10), Hp(3) and Hp(0.07) were estimated for the staff for 2 months. According to the results obtained in this study, the equivalent dose of the gastroenterologist's body, eye lenses and hands was 0.045 ± 0.001 mSv, 0.111 ± 0.014 mSv and 0.357 ± 0.034 $\mathrm{mSv}$, respectively. This study showed that the annual radiation exposure for ERCP department staff of Abu Ali Sinai Hospital is less than the annual dose limit. However, if the principles of proper radiation protection and individual dosimetry are followed, the dose to staff members can be reduced.[Abstract] [Full Text] [Related] [New Search]