These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Correlation between cephalic screw positioning of Standard Gamma 3 Nail for intertrochanteric fractures and cut-out incidence.
    Author: Ortolani A, Lana D, Martucci A, Pesce F, Stallone S, Milani L, Urso R, Melucci G, Tigani D.
    Journal: SICOT J; 2024; 10():9. PubMed ID: 38415767.
    Abstract:
    INTRODUCTION: Lateral fractures of proximal femur are the most frequent fractures in elderly people. Internal fixation using medullary nails is the gold standard of treatment (Gamma 3 nail is the most implanted device) due to reduced incidence of complications than other devices. We report our experience in treating this kind of fractures with Gamma 3 nail, between January 2015 and December 2021. METHODS: We performed a retrospective cohort study of patients treated in our orthopaedic department; level of clinical care is III: 559 patients (431 females and 128 males, with an average age of 85.3 years) with lateral femoral neck fracture. All patients were surgically treated with Gamma 3 standard nail (SGN). We evaluated preliminary X-rays to classify fractures, according to AO-OTA classification and post-operative X-ray to verify cephalic screw position site, according to areas described by Cleveland in 1959: we measured tip-to-apex distance (TAD) and tip-to-apex calcar referred distance (CalTAD). Finally Chang reduction quality criteria (CRQC) for fracture reduction of trochanteric fractures were determined using preoperative or postoperative Antero-Posterior (AP) and lateral radiographs in a Picture Archiving and Communication System (PACS). Incidence of cut-out was evaluated in relation with these parameters. Patients were divided into 2 groups: first group had cephalic screw in optimal positions (5-8-9), the other group had cephalic screw in other positions. RESULTS: In 328 patients (58.7%) screw was in positions 5-8-9, in 231 patients (41.2%) screw was in not-optimal position. Median TAD was 19.1 ± 7.0 mm (range = 0.0-50.5); in 463 patients (82.8%) TAD was ≤ 25 mm. Median CalTAD was 21.4 ± 4.7 mm (range = 5.7-39.2); in 105 patients (79.4%) CalTAD was ≤ 25 mm. Cut-out was observed in 8 cases (1.43%). Multivariate analysis showed a significant correlation (p < 0,05) between incidence of cut-out and fracture type 31A2 and with TAD values >25 mm. Cephalic screw position did not influence incidence of cut-out. DISCUSSION: In order to obtain fracture healing with a low risk of failure, in particular cut-out, it is necessary to obtain good reduction of fracture and optimal lag screw position in order to achieve a TAD inferior to 25 mm.
    [Abstract] [Full Text] [Related] [New Search]