These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Clinic-based evaluation of the dual Xpert CT/NG assay on the GeneXpert System for screening for extragenital chlamydial and gonococcal infections amongst men who have sex with men. Author: Cordioli M, Gios L, Erbogasto A, Mirandola M, Sandri A, Padovese V, Caceres C, Vargas S, Blondeel K, Silva R, Kiarie J, Kurbonov F, Peeling RW, Thwin SS, Golparian D, Unemo M, Toskin I, ProSPeRo Network. Journal: BMC Infect Dis; 2024 Feb 29; 24(Suppl 1):224. PubMed ID: 38418963. Abstract: BACKGROUND: Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) infections have increased globally. Asymptomatic infections represent a significant risk of long-term complications. Men who have sex with men (MSM) are disproportionally affected, underscoring the need to offer screening programmes to this population. CT/NG Point of Care Testing (POCT) constitutes a strategic tool to improve the continuum of STI care, however extensive real-life evaluations amongst at risk populations are lacking. The aim of this study is to estimate the GeneXpert CT/NG assay performance and usability for CT and NG at genital and extragenital sites for screening amongst MSM. METHODS: This study was a multi-site sexual health clinic-based evaluation (Italy, Malta and Peru) with consecutive enrolment. A first void urine sample (divided in two aliquots), two oropharyngeal and two anorectal swabs were collected for each study participant. One specimen set (one for each anatomical site) was tested with the dual index test (Cepheid) at the clinics by the healthcare staff, the other set with FDA/CE approved Nucleic Acid Amplification Tests (NAATs) at the laboratory. Clinical sites and reference laboratories participated in an internal and external quality control programme. Sensitivity, specificity, positive and negative likelihood ratios, positive and negative predictive values for each anatomical site were estimated using a meta-analytic approach. RESULTS: One thousand seven hundred two MSM were recruited across all clinical sites for a total of 5049 biological specimens. NG and CT were respectively detected in 274 and 287 of samples. Overall, the NG POCT sensitivity and specificity was 91.43% and 99.75% in urine (LR + 372.80, LR- 0.09), 89.68% and 99.55% in rectal specimens (LR + 197.30, LR- 0.10) and 75.87% and 98.77% at the pharynx respectively (LR + 61.94, LR- 0.24). The CT component of the POCT sensitivity was 84.82% and specificity 99.63% in urine (LR + 228.68, LR- 0.15), 78.07% and 99.19% respectively on rectal site (LR + 96.23, LR-0.22), 67.79% and 99.88% respectively at pharyngeal site (LR + 554.89, LR- 0.32). 95.95% of MSM reported to be willing to wait for POCT results and no provider reported difficulties in terms of performance or interpretation of the results of the Xpert CT/NG. CONCLUSION: Rapid turnaround time, ease of use and high acceptability make the Xpert CT/NG testing system a strategic tool for increasing testing frequency, reaching those not yet tested and offering the possibility of immediate treatment if needed. The assay showed good negative likelihood ratios and confirms its use to rule out CT/NG infections. Sensitivity varied across sites and pathogens. Periodic staff training at the testing sites should be mandatory.[Abstract] [Full Text] [Related] [New Search]