These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Effect of connector height and retainer occlusal thickness on the fracture resistance of posterior 4-unit monolithic 5Y-TZP fixed partial dentures after thermomechanical aging. Author: ElShamoty YK, Sadeqi HA, Baig MR. Journal: J Prosthet Dent; 2024 May; 131(5):933.e1-933.e7. PubMed ID: 38429151. Abstract: STATEMENT OF PROBLEM: The connector height and retainer occlusal thickness of fixed partial dentures (FPDs) may affect restoration longevity. PURPOSE: The purpose of this in vitro study was to determine and compare the fracture resistance of 4-unit monolithic 5% yttria tetragonal zirconia polycrystal (5Y-TZP) FPDs made with different connector heights and retainer occlusal thicknesses after thermomechanical aging. MATERIAL AND METHODS: Forty test metal dies were duplicated from a master metal die containing 2 anatomic abutment preparations of the mandibular right first premolar and second molar for a 4-unit FPD. The dies were divided into 2 groups of 20 each for the fabrication of 4-unit FPDs, with 2-mm and 4-mm uniform connector heights at all 3 connectors, resulting in 6.3-mm2 and 12.6-mm2 connector areas. Each of these groups was further divided into 2 subgroups based on the occlusal thickness of the 2 retainers of 1 mm and 2 mm (n=10). Polyvinyl siloxane impressions of the test metal dies were made and poured in Type V dental stone. Laboratory scans were performed on all the stone dies, and 40 5Y-TZP FPDs (Ceramill Zolid FX) were designed and fabricated. Subsequently, all the FPDs were luted on to the metal dies with a self-adhesive resin cement. The FPDs were preloaded (400 000 mechanical cycles; 4000 thermocycles) using a mastication simulator and tested for axial compressive strength. Two-way analysis of variance (ANOVA) was used to examine the effect of connector and occlusal thicknesses on the fracture load (α=.05). The data were further assessed using the post hoc Tukey HSD multiple comparison test (α=.05). RESULTS: The mean fracture load values were between 737 N and 1563 N. Significant differences in the mean fracture load were found between the connector heights (601 N; P<.001) and occlusal thicknesses (225 N; P=.002), but the interaction of the 2 factors was not significant (P=.132) The Tukey post hoc analysis showed significant differences between the connector thicknesses groups (P<.01), but the occlusal thicknesses were found to be similar for the same connector height (P=.609) CONCLUSIONS: Connector height and occlusal retainer thickness influenced the fracture load of 4-unit monolithic 5Y-TZP FPDs after thermomechanical aging.[Abstract] [Full Text] [Related] [New Search]