These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Fast and accessible T2 mapping using off-resonance corrected DESPOT2 with application to 3D prostate.
    Author: Coronado R, Castillo-Passi C, Besa C, Irarrazaval P.
    Journal: Magn Reson Imaging; 2024 Jun; 109():227-237. PubMed ID: 38508291.
    Abstract:
    PURPOSE: Most T1 and T2 mapping take long acquisitions or needs specialized sequences not widely accessible on clinical scanners. An available solution is DESPOT1/T2 (Driven equilibrium single pulse observation of T1/T2). DESPOT1/T2 uses Spoiled gradient-echo (SPGR) and balanced Steady-State Free Precession (bSSFP) sequences, offering an accessible and reliable way for 3D accelerated T1/T2 mapping. However, bSSFP is prone to off-resonance artifacts, limiting the application of DESPOT2 in regions with high susceptibility contrasts, like the prostate. Our proposal, DESPO+, employs the full bSSFP and SPGR models with a dictionary-based method to reconstruct 3D T1/T2 maps in the prostate region without off-resonance banding. METHODS: DESPO+ modifies the bSSFP acquisition of the original variable flip angle DESPOT2. DESPO+ uses variable repetition and echo times, employing a dictionary-based method of the full bSSFP and SPGR models to reconstruct T1, T2, and Proton Density (PD) simultaneously. The proposed DESPO+ method underwent testing through simulations, T1/T2 phantoms, and on fourteen healthy subjects. RESULTS: The results reveal a significant reduction in T2 map banding artifacts compared to the original DESPOT2 method. DESPO+ approach reduced T2 errors by up to seven times compared to DESPOT2 in simulations and phantom experiments. We also synthesized in-vivo T1-weighted/T2-weighted images from the acquired maps using a spin-echo model to verify the map's quality when lacking a reference. For in-vivo imaging, the synthesized images closely resemble those from the clinical MRI protocol, reducing scan time by around 50% compared to traditional spin-echo T1-weighted/T2-weighted acquisitions. CONCLUSION: DESPO+ provides an off-resonance insensitive and clinically available solution, enabling high-resolution 3D T1/T2 mapping and synthesized T1-weighted/T2-weighted images for the entire prostate, all achieved within a short scan time of 3.6 min, similar to DESPOT1/T2.
    [Abstract] [Full Text] [Related] [New Search]