These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Translation, cross-cultural adaptation, and validation of the 10-item spine functional index (SFI-10) in the Brazilians with musculoskeletal spine disorders. Author: do Nascimento Freitas DW, Dibai-Filho AV, Pontes-Silva A, Araujo GGC, de Oliveira AR, da Cunha Leal P, Gabel CP, Fidelis-de-Paula-Gomes CA, Cabido CET. Journal: BMC Musculoskelet Disord; 2024 Apr 05; 25(1):266. PubMed ID: 38575902. Abstract: PURPOSE: To translate and cross-culturally adapt the Spine Functional Index (SFI) into Brazilian Portuguese (SFI-Br) in individuals with musculoskeletal spine disorders. METHODS: Participants (n=194) answered the Numerical Pain Rating Scale (NPRS), 36-item Short-Form Health Survey (SF-36), Roland-Morris Disability Questionnaire for General Pain (RMDQ-g), and SFI-25 incorporating the SFI-10. Structural validity, from confirmatory factor analysis (CFA), used comparative fit index (CFI), Tucker-Lewis index (TLI), root mean square error of approximation (RMSEA), and chi-square/degrees of freedom (DF). The best structure was considered from the lower values of the Akaike Information Criterion (AIC) and Bayesian Information Criterion (BIC). Construct and criterion validity used Spearman's correlation coefficient (rho). Internal consistency used Cronbach's alpha, reliability used intraclass correlation coefficient (ICC2,1), with ceiling and floor effects determined. Error used the standard error of the measurement (SEM) and minimal detectable change, 90% level (MDC90). RESULTS: Adequate fit indices demonstrated an unequivocal one-factor structure only for the SFI-10 (chi-square/DF <3.00, CFI and TLI >0.90, RMSEA <0.08). The SFI-10-Br correlation was high with the SFI-Br (rho=0.914, p<0.001), moderate for the RMDQ-g (rho=-0.78), SF-36 functional capacity domain (rho=0.718) and NPRS (rho=-0.526); and adequate for the remaining SF-36 domains (rho>0.30). Test-retest reliability (ICC2,1=0.826) and internal consistency (alpha=0.864) were high. No ceiling or floor effects were observed, and error was satisfactory (SEM=9.08%, MDC90=25.15%). CONCLUSION: The SFI Brazilian version was successfully produced with the 10-item version showing an unequivocal one-factor structure, high construct and criterion validity, reliability, internal consistency, and satisfactory error. Further research on responsiveness is required.[Abstract] [Full Text] [Related] [New Search]