These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Tacrolimus Monitoring in Liver Transplant Recipients, Posttransplant Cholestasis: A Comparative Between 2 Commercial Immunoassays and a Liquid Chromatography-Tandem Mass Spectrometry Method.
    Author: Parant F, Delignette MC, Charpiat B, Lacaille L, Lebosse F, Monneret G, Mohkam K, Mabrut JY, Aubrun F, Heyer L, Antonini T.
    Journal: Ther Drug Monit; 2024 Aug 01; 46(4):446-455. PubMed ID: 38648663.
    Abstract:
    BACKGROUND: Cholestasis commonly occurs after orthotopic liver transplantation. It can be extrahepatic because of mechanical obstruction or intrahepatic because of various causes. During cholestasis episodes, blood concentrations of tacrolimus (TAC) metabolites may increase, potentially affecting TAC concentrations measured by immunoassays. This study aimed to simultaneously evaluate the analytical performance of 2 TAC immunoassays, a quantitative microsphere system (QMS) immunoassay, and chemiluminescence microparticle immunoassay, using liquid chromatography-tandem mass spectrometry (LC-MS/MS) as a reference method in liver transplant recipients. METHODS: This single-center study included 265 patients who underwent orthotopic liver transplantation. In total, 942 blood samples were collected. TAC trough concentrations were measured using LC-MS/MS and 2 immunoassays in parallel. The plasma concentrations of conjugated bilirubin were measured in all samples. The results were analyzed using Bland-Altman plots and Passing-Bablok regressions. RESULTS: The Bland-Altman plot analysis showed that the TAC QMS immunoassay has a significant bias (+37%) compared with LC-MS/MS, and this bias was higher in patients with cholestasis with hyperbilirubinemia (≤+70% in patients with conjugated bilirubin >150 µmol/L). In comparison, the chemiluminescence microparticle immunoassay showed acceptable analytical performance in patients with hyperbilirubinemia (bias <10%). CONCLUSIONS: In agreement with previous findings, the TAC QMS immunoassay showed a positive bias compared with LC-MS/MS. This bias is remarkably high in patients with cholestasis and hyperbilirubinemia, suggesting the cross-reactivity of TAC metabolites with the monoclonal antibody used in the QMS immunoassay.
    [Abstract] [Full Text] [Related] [New Search]