  • Title: An electrochemical sensor based on molecularly imprinted poly(o-phenylenediamine) for the detection of thymol.
    Author: Dong J, Zhang H, Ding Z, Li J, Xu L, Kong Y, Zheng G.
    Journal: Anal Biochem; 2024 Aug; 691():115551. PubMed ID: 38702023.
    Abstract:
    A molecularly imprinted electrochemical sensor was facilely fabricated for the detection of thymol (THY). o-Phenylenediamine (oPD) was used as the functional monomer and electropolymerized on the surface of the glassy carbon electrode (GCE) by using THY as the templates. After the THY templates were removed with 50 % (v/v) ethanol, imprinted cavities complementary to the templates were formed within the poly(o-phenylenediamine) (PoPD) films. The resultant molecularly imprinted PoPD/GCE (MI-PoPD/GCE) was used for the detection of THY, and a wide linear range from 0.5 to 100 μM with a low limit of detection (LOD) of 0.084 μM were obtained under the optimal conditions. The developed MI-PoPD/GCE also displays high selectivity, reproducibility and stability for THY detection. Finally, the content of THY in the real samples was accurately determined by the as-fabricated MI-PoPD/GCE, demonstrating its high practicability and reliability.