These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Evaluation of Relative Dentin Abrasivity in Whitening Toothpastes Containing Acids. Author: Kim JH, Miletic V, Leprince JG, Park YS. Journal: Int Dent J; 2024 Oct; 74(5):1044-1052. PubMed ID: 38762371. Abstract: INTRODUCTION AND AIMS: This study aimed to evaluate the relative dentin abrasivity of whitening toothpastes containing acids using the Radioactive Dentin Abrasivity - Profilometry Equivalent (RDA-PE). METHODS: A total of 100 bovine dentin specimens were prepared and assigned to the following groups (n = 10): 5 hydrogen peroxide (HP) whitening toothpastes (WTH1-WTH5) with or without acid (citric acid, ethylenedinitrilotetraacetic acid disodium, and phosphoric acid), 2 whitening toothpastes with silica and containing citric or phosphoric acid (WTS1 and WTS2), one conventional toothpaste (CT), and 2 reference slurries (RS). All specimens were brushed for 4,000 or 10,000 strokes using toothbrush and toothbrushing machine. The average dentin depth was measured using a noncontact profilometery, and the RDA-PE value was calculated based on the RS. The pH of the solution, average particle size, particle content, and particle hardness were measured. The RDA-PE data were analysed using one-way analysis of variance and Tukey's test, and the effects of the 4 measured factors on RDA-PE were investigated via multiple regression analysis. RESULTS: The RDA-PE values of the HP whitening toothpastes (mean value: 19-46) were significantly lower, whereas those of the silica whitening toothpastes (80 or 111) were similar to those of the RS after 4,000 strokes (100). The RDA-PE values of all whitening toothpastes were significantly lower than the RS values after 10,000 strokes (242). The HP whitening toothpastes were slightly acidic (pH ≤6) compared to the other solutions. The HP (2.9%-3.7%) and silica (8.9% or 9.9%) whitening toothpastes had significantly lower particle content than RS (16.6%). The particle content significantly influenced the RDA-PE values by multiple regression results. CONCLUSIONS: The RDA-PE values of whitening toothpastes varied. The particle content in the solution was a key factor affecting the RDA-PE value. CLINICAL RELEVANCE: Whitening toothpastes containing acids did not cause significant dentin abrasion.[Abstract] [Full Text] [Related] [New Search]