These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Heavy-intensity priming exercise extends the V̇o2max plateau and increases peak-power output during ramp-incremental exercise.
    Author: Marinari G, Iannetta D, Holash RJ, Zagatto AM, Keir DA, Murias JM.
    Journal: Am J Physiol Regul Integr Comp Physiol; 2024 Aug 01; 327(2):R164-R172. PubMed ID: 38842514.
    Abstract:
    This study investigated whether a heavy-intensity priming exercise precisely prescribed within the heavy-intensity domain would lead to a greater peak-power output (POpeak) and a longer maximal oxygen uptake (V̇o2max) plateau. Twelve recreationally active adults participated in this study. Two visits were required: 1) a step-ramp-step test [ramp-incremental (RI) control], and 2) an RI test preceded by a priming exercise within the heavy-intensity domain (RI primed). A piecewise equation was used to quantify the V̇o2 plateau duration (V̇o2plateau-time). The mean response time (MRT) was computed during the RI control condition. The delta (Δ) V̇o2 slope (S; mL·min-1·W-1) and V̇o2-Y intercept (Y; mL·min-1) within the moderate-intensity domain between conditions (RI primed minus RI control) were also assessed using a novel graphical analysis. V̇o2plateau-time (P = 0.001; d = 1.27) and POpeak (P = 0.003; d = 1.08) were all greater in the RI primed. MRT (P < 0.001; d = 2.45) was shorter in the RI primed compared with the RI control. A larger ΔV̇o2plateau-time was correlated with a larger ΔMRT between conditions (r = -0.79; P = 0.002). This study demonstrated that heavy-intensity priming exercise lengthened the V̇o2plateau-time and increased POpeak. The overall faster RI-V̇o2 responses seem to be responsible for the longer V̇o2plateau-time. Specifically, a shorter MRT, but not changes in RI-V̇o2-slopes, was associated with a longer V̇o2plateau-time following priming exercise.NEW & NOTEWORTHY It remains unclear whether priming exercise extends the maximal oxygen uptake (V̇o2max) plateau and increases peak-power output (POpeak) during ramp-incremental (RI) tests. This study demonstrates that a priming exercise, precisely prescribed within the heavy-intensity domain, extends the plateau at V̇o2max and leads to a greater POpeak. Specifically, the extended V̇o2max plateau was associated with accelerated RI-V̇o2 responses.
    [Abstract] [Full Text] [Related] [New Search]