These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Association of Integrase Strand Transfer Inhibitor-Based Antiretroviral Therapy With Blood Pressure and Sustained Hypertension in People With Human Immunodeficiency Virus. Author: Siddiqui M, Burkholder GA, Judd E, Wang Z, Colantonio LD, Ghazi L, Shimbo D, Willig AL, Overton ET, Oparil S, Levitan EB, Heath SL, Muntner P. Journal: Am J Hypertens; 2024 Sep 16; 37(10):759-768. PubMed ID: 38890772. Abstract: BACKGROUND: Integrase strand transfer inhibitors (INSTIs) are a commonly used antiretroviral therapy (ART) class in people with human immunodeficiency virus (HIV) and associated with weight gain. We studied the association of INSTI-based ART with systolic and diastolic blood pressure (SBP and DBP). METHODS: We recruited 50 people taking INSTI-based ART and 40 people taking non-INSTI-based ART with HIV and hypertension from the University of Alabama at Birmingham HIV clinic. Office BP was measured unattended using an automated (AOBP) device. Awake, asleep, and 24-hour BP were measured through ambulatory BP monitoring. Among participants with SBP ≥130 mm Hg or DBP ≥80 mm Hg on AOBP, sustained hypertension was defined as awake SBP ≥130 mm Hg or DBP ≥80 mm Hg. RESULTS: Mean SBP and DBP were higher among participants taking INSTI- vs. non-INSTI-based ART (AOBP-SBP/DBP: 144.7/83.8 vs. 135.3/79.3 mm Hg; awake-SBP/DBP: 143.2/80.9 vs. 133.4/76.3 mm Hg; asleep-SBP/DBP: 133.3/72.9 vs. 120.3/65.4 mm Hg; 24-hour-SBP/DBP: 140.4/78.7 vs. 130.0/73.7 mm Hg). After multivariable adjustment, AOBP, awake, asleep, and 24-hour SBP were 12.5 (95% confidence interval [CI] 5.0-20.1), 9.8 (95% CI 3.6-16.0), 10.4 (95% CI 2.0-18.9), and 9.8 (95% CI 4.2-15.4) mm Hg higher among those taking INSTI- vs. non-INSTI-based ART, respectively. AOBP, awake, asleep, and 24-hour DBP were 7.5 (95% CI 0.3-14.6), 6.1 (95% CI 0.3-11.8), 7.5 (95% CI 1.4-13.6), and 6.1 (95% CI 0.9-11.3) mm Hg higher among those taking INSTI- vs. non-INSTI-based ART after multivariable adjustment. All participants had SBP ≥130 mm Hg or DBP ≥80 mm Hg on AOBP and 97.9% and 65.7% of participants taking INSTI- and non-INSTI-based ART had sustained hypertension, respectively. CONCLUSIONS: INSTI-based ART was associated with higher SBP and DBP than non-INSTI-based ART.[Abstract] [Full Text] [Related] [New Search]