These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Role of quantitative imaging biomarkers in an early FDG-PET/CT for detection of immune-related adverse events in melanoma patients: a prospective study. Author: Hribernik N, Strasek K, Huff DT, Studen A, Zevnik K, Skalic K, Jeraj R, Rebersek M. Journal: Radiol Oncol; 2024 Sep 01; 58(3):335-347. PubMed ID: 39287171. Abstract: BACKGROUND: To evaluate the role of the novel quantitative imaging biomarker (QIB) SUVX% of 18F-FDG uptake extracted from early 18F-FDG-PET/CT scan at 4 weeks for the detection of immune-related adverse events (rAE) in a cohort of patients with metastatic melanoma (mM) patients receiving immune-checkpoint inhibitors (ICI). PATIENTS AND METHODS: In this prospective non-interventional, one-centre clinical study, patients with mM, receiving ICI treatment, were regularly followed by 18F-FDG PET/CT. Patients were scanned at baseline, early point at week four (W4), week sixteen (W16) and week thirty-two (W32) after ICI initiation. A convolutional neural network (CNN) was used to segment three organs: lung, bowel, thyroid. QIB of irAE - SUVX% - was analyzed within the target organs and correlated with the clinical irAE status. Area under the receiver-operating characteristic curve (AUROC) was used to quantify irAE detection performance. RESULTS: A total of 242 18F-FDG PET/CT images of 71 mM patients were prospectively collected and analysed. The early W4 scan showed improved detection only for the thyroid gland compared to W32 scan (p=0.047). The AUROC for detection of irAE in the three target organs was highest when SUVX% was extracted from W16 scan and was 0.76 for lung, 0.53 for bowel and 0.81 for thyroid. SUVX% extracted from W4 scan did not improve detection of irAE compared to W16 scan (lung: p = 0.54, bowel: p = 0.75, thyroid: p = 0.3, DeLong test), as well as compared to W32 scan in lungs (p = 0.32) and bowel (p = 0.3). CONCLUSIONS: Early time point 18F-FDG PET/CT at W4 did not lead to statistically significant earlier detection of irAE. However, organ 18F-FDG uptake as quantified by SUVX% proved to be a consistent QIB of irAE. To better assess the role of 18F-FDG PET/CT in irAE detection, the time evolution of 18F-FDG PET/CT quantifiable inflammation would be of essence, only achievable in multi centric studies.[Abstract] [Full Text] [Related] [New Search]