Search MEDLINE/PubMed
Title: A false-positive indium-111 labeled leukocyte scintigram in a patient with a painful hip prosthesis. Author: Feldman N, Makler PT, Alavi A. Journal: Clin Nucl Med; 1986 Jan; 11(1):38-9. PubMed ID: 3943241. Abstract: A Tronzo hip prosthesis is designed to elicit an inflammatory reaction in order to promote prosthesis stability. A three-phased bone scan and Ga-67 imaging in conjunction with physical examination and laboratory findings failed to demonstrate evidence for osteomyelitis in a patient with a painful hip prosthesis, in whom images obtained with In-111-labeled leukocytes were positive. This observation demonstrated that the interpretation of the latter technique in demonstrating inflammation can cause a false impression of an infectious process.[Abstract] [Full Text] [Related] [New Search]