    Monitoring of brainstem auditory evoked potentials (BAEP) during neurological surgery can provide useful information. However, in order to interpret intraoperative BAEP changes, it is necessary to delineate the influence of anesthesia, including inhalation agents. In this study, we examined the influence of isoflurane and isoflurane-nitrous oxide anesthesia on BAEP in ten healthy volunteers during normothermic, normocapnic, and normotensive conditions. Isoflurane significantly increased the latencies of peaks III, IV, and V at all end-tidal concentrations studied (1.0%, 1.5%, and 2.0%). Addition of 50% nitrous oxide did not influence these findings. The increase in latencies with isoflurane anesthesia, however, was nonlinear and appeared to plateau after 1.5%. We suggest that during isoflurane anesthesia, an intraoperative increase in peak V latency beyond 1.0 msec is best explained by factors other than direct effects of isoflurane.