These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Potency of isoflurane and nitrous oxide in conventional swine.
    Author: Eisele PH, Talken L, Eisele JH.
    Journal: Lab Anim Sci; 1985 Feb; 35(1):76-8. PubMed ID: 3981962.
    Abstract:
    The minimum alveolar concentration (MAC) of isoflurane in oxygen (O2) was determined to be 1.55 +/- 0.08 (SEM) volumes % in twelve pigs (Sus scrofa). Values for isoflurane MAC in the presence of 50% (I-50%N2O) and 66% (I-66%N2O) nitrous oxide were determined in nine and six of these same animals, respectively, and equalled 1.03 +/- 0.05 vol % for I-50%N2O and 0.95 +/- 0.07 vol % for I-66%N2O. Animals respired spontaneously and arterial blood pressure (AP), heart rate (HR), rectal body temperature, and arterial blood gases (PO2, PCO2, and pH) were recorded throughout the study period. These parameters were within normal limits near MAC for all three gas combinations. The MAC for isoflurane in swine was similar to that for other animals and, man and the use of this agent was associated with rapid and uneventful anesthetic induction and recovery. The addition of 50% and 66% nitrous oxide (N2O) reduced the isoflurane MAC by 30% and 42%, respectively.