These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Calculation of effective renal plasma flow using 125I-orthoiodohippuran: comparison of four methods.
    Author: Taylor DJ, Griffiths P, Swainson CP, Bailey RR, Turner JG.
    Journal: Clin Nephrol; 1985 Apr; 23(4):169-72. PubMed ID: 4006326.
    Abstract:
    Fifty-three determinations of effective renal plasma flow (ERPF) were made on 21 patients with a wide range of renal function. Serial plasma samples for 6 hours after the injection of 125I-orthoiodohippurate were used to plot the plasma disappearance curve, and a standard ERPF was calculated using biexponential analysis of the curve. ERPF values calculated by 3 published approximation methods using limited plasma samples were compared to the standard values. All approximation methods overestimated the ERPF, the mean percentage error lying between + 18.3% +/- 20.4% and + 70.0% +/- 51.3%. With 2 of the 3 approximation methods the overestimation was particularly prominent in patients with moderate to severe renal insufficiency (ERPF less than 300 ml/min). For research purposes the more accurate and reliable biexponential method of analysis of ERPF is recommended.
    [Abstract] [Full Text] [Related] [New Search]