These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Percutaneous ventriculocisternal shunt. Technical note.
    Author: Fox JL, Al-Mefty O.
    Journal: Surg Neurol; 1985 Aug; 24(2):184-6. PubMed ID: 4012576.
    Abstract:
    A modification of the Torkildsen ventriculocisternal shunting procedure, used successfully in a patient with bilateral obstruction of the foramina of Monro, is described. Through bilateral occipital burr holes, a "U-tube" system interconnected the two lateral ventricles. Spinal fluid was then drained with a separate Spetzler catheter passed from one lateral ventricle into the cisterna magna. A posterior percutaneous insertion technique (standard puncture of the cisterna magna) was used to place the catheter into this subarachnoid space.