These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Dynamic subaortic obstruction in hypertrophic cardiomyopathy: analysis by pulsed Doppler echocardiography. Author: Maron BJ, Gottdiener JS, Arce J, Rosing DR, Wesley YE, Epstein SE. Journal: J Am Coll Cardiol; 1985 Jul; 6(1):1-18. PubMed ID: 4040139. Abstract: To determine whether true obstruction to left ventricular ejection exists in patients with hypertrophic cardiomyopathy and a subaortic gradient, pulsed Doppler echocardiography was used to analyze the patterns of left ventricular emptying in 50 patients with hypertrophic cardiomyopathy (20 with and 30 without evidence of obstruction) and in 20 normal subjects. In obstructive hypertrophic cardiomyopathy, left ventricular ejection was characterized by early and rapid emptying (76 +/- 14% of aortic flow velocity in the initial one-third of systole). The proportion of forward flow velocity occurring before initial mitral-septal contact (and hence, by inference before the onset of the subaortic gradient) was variable, but averaged 58%. In contrast, the proportion of forward flow velocity occurring after mitral-septal contact (and, therefore, concomitant with the gradient and increased intraventricular pressure) was considerable, averaging over 40%. Mid-systolic impedance to left ventricular outflow was suggested by the rapid deceleration in aortic flow velocity concomitant with mitral-septal contact and premature partial aortic valve closure. Furthermore, left ventricular ejection was prolonged (384 +/- 40 ms) and the ventricle continued to empty and shorten during the period when both the pressure gradient and markedly increased intraventricular pressures were present. In 16 of 20 patients, a relatively small second peak in flow velocity appeared in late systole. Since marked systolic anterior motion of the mitral valve was still present, the late systolic portion of forward flow velocity also appeared to be largely ejected during imposition of a mechanical impediment to outflow. In contrast, patients with nonobstructive hypertrophic cardiomyopathy showed no evidence of impedance to left ventricular ejection. Aortic flow velocity waveforms were similar to those of normal subjects, with flow persisting to aortic valve closure; significant mitral systolic anterior motion and partial mid-systolic aortic valve closure were absent, and the systolic ejection period was normal (303 +/- 27 ms).(ABSTRACT TRUNCATED AT 400 WORDS)[Abstract] [Full Text] [Related] [New Search]