These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Pulmonary atelectasis formation during diving with closed-circuit oxygen breathing apparatus. Author: Dahlbäck GO, Balldin UI. Journal: Undersea Biomed Res; 1985 Jun; 12(2):129-37. PubMed ID: 4071842. Abstract: The physiological effects of diving with two types of closed-circuit oxygen breathing apparatus were investigated in 4 divers. In one apparatus the breathing bag was mounted on the dorsum and in the other on the chest, inducing -2 kPa and +1 to +2 kPa static lung load in the prone position, respectively. The back-mounted bag caused an unfavorable swimming position, with increased heart rate, breathing rate, and rating of perceived exertion (RPE) for work load. The greater internal and external work of breathing (the latter judged from the higher RPE for breathing resistance) probably contributed to a higher RPE for discomfort with the back-mounted bag. Three divers showed great reduction in vital capacity (VC) (0.8 to 1.9 liters) and developed coughing attacks after dives with this apparatus; these results were interpreted as possible indications of atelectasis formation. The 4th diver showed slight reduction in VC with both types of bag, possibly because the changes in static lung loads did not influence the airway closure in this man.[Abstract] [Full Text] [Related] [New Search]