These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Leucocyte esterase-nitrite screening method for pyuria and bacteriuria. Author: Wilkins EG, Ratcliffe JG, Roberts C. Journal: J Clin Pathol; 1985 Dec; 38(12):1342-5. PubMed ID: 4078016. Abstract: The value of the one minute leucocyte esterase-nitrite chemical strips as a screening procedure for detecting appreciable levels of pyuria and bacteriuria was assessed by comparison with microscopy and culture results. The likelihood that a negative leucocyte esterase result indicated less than 10 white cells/cu mm by microscopy (the negative predictive value), was 90.1% and that a negative nitrite result indicated less than 10(5) organisms/ml was 91.3%. There were many false positive results with both tests, however, and the overall predictive value of a positive leucocyte esterase or nitrite test, or both, was low. The leucocyte esterase-nitrite strip was neither sufficiently sensitive nor specific enough to be used as a cost effective method for screening urines in the laboratory.[Abstract] [Full Text] [Related] [New Search]