Search MEDLINE/PubMed
Title: [Ocular hemodynamics in central and branch artery occlusions]. Author: Christ T, Stodtmeister R, Pillunat L. Journal: Klin Monbl Augenheilkd; 1985 Nov; 187(5):443-4. PubMed ID: 4087808. Abstract: Ocular oscillodynamograms (OODG) were made in 9 patients with an occlusion of the central artery and 11 patients with an occlusion of one branch artery. While there were no pathologic findings in patients with branch artery occlusions, it was not possible to record any systolic-retinal oscillations of the pulse in patients with an occlusion of the central artery. In three cases the systolic ciliary perfusion pressure was also low owing to carotid stenosis.[Abstract] [Full Text] [Related] [New Search]