Title: Evaluation of relationship between hearing threshold and loudness discomfort level in sensorineural hearing loss. Author: Shapiro I. Journal: J Speech Hear Disord; 1979 Feb; 44(1):31-6. PubMed ID: 423553. Abstract: The relationship between hearing level and loudness discomfort level (LDL) for narrow-band noise was evaluated in two groups of patients with sensorineural hearing loss. Group I had thresholds ranging from 25-60 dB SPL and Group II's thresholds ranged from 65-100 dB SPL. LDLs were determined for narrow bands of noise centered at 500, 1000, 2000, and 4000 Hz. The LDLs for Group II were greater than those for Group I and the differences were statistically significant. It is speculated that one reason for others not finding differences as a function of hearing level may be the absence of severe to profound hearing loss in the test populations.[Abstract] [Full Text] [Related] [New Search]