These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Pericardial fluid gas analysis in hemorrhagic pericardial tamponade.
    Author: Balakrishnan S, Hartman CW, Grinnan GL, Bartel AG, Crisler C, Brickman RD.
    Journal: Ann Thorac Surg; 1979 Jan; 27(1):55-8. PubMed ID: 453958.
    Abstract:
    Nine patients with hemorrhagic pericardial tamponade were studied to determine the localizing value of gas analysis of pericardial fluid in therapeutic pericardiocentesis. The aspirate and the central venous blood was analyzed simultaneously for partial pressure of oxygen (PO2), partial pressure of carbon dioxide (PCO2), and hematocrit at the time of pericardiocentesis. In all 9 patients the difference in hematocrit between the pericardial fluid and the central venous blood was not significant. The PCO2 of pericardial fluid was significantly higher than that of central venous blood (p less than 0.025). The PO2 of pericardial fluid was consistently and significantly lower than that of central venous blood (p less than 0.005). We conclude that in patients with hemorrhagic pericardial tamponade, the simultaneous measurement of PO2 and PCO2 of central venous blood and pericardial fluid is a useful rapid bedside method to confirm the site of aspiration during pericardiocentesis. The PO2 determination is statistically the best discriminator between the two fluids in this setting.
    [Abstract] [Full Text] [Related] [New Search]