These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Accommodative and fusional components of fixation disparity. Author: Semmlow JL, Hung G. Journal: Invest Ophthalmol Vis Sci; 1979 Oct; 18(10):1082-6. PubMed ID: 478778. Abstract: Traditional measurements of fixation disparity, like other binocular measurements, confound influences from both blur-driven and disparity-driven components. Measuring fixation disparity with accommodation open-loop eliminates accommodative interactions, and results show fixation disparity is reduced to about half the value observed normally for high levels of forced vergence. Thus fixation disparity curves are shaped by both accommodative and fusional vergence processes.[Abstract] [Full Text] [Related] [New Search]