These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Stability-indicating assay of acetaminophen in an effervescent tablet by ion-pair high-performance liquid chromatography.
    Author: Sena FJ, Piechocki JT, Li KL.
    Journal: J Pharm Sci; 1979 Nov; 68(11):1465-6. PubMed ID: 512905.
    Abstract:
    A stability-indicating analytical method is described for determining acetaminophen and its degradation product, p-aminophenol, in an affervescent tablet. Tablets assayed by ion-pair high-performance reversed-phase liquid partition chromatography required no sample cleanup. The method applied to tablets containing 325 mg of acetaminophen yielded an average recovery of 99.6% with a relative standard deviation of 0.70% (n = 10). As little as 0.005% p-aminophenol could be detected.
    [Abstract] [Full Text] [Related] [New Search]