  • Title: Direct gas chromatographic determination of carbamate pesticides using Carbowax 20M-modified supports and the electrolytic conductivity detector.
    Author: Hall RC, Harris DE.
    Journal: J Chromatogr; 1979 Feb 01; 169():245-59. PubMed ID: 536418.
    Abstract:
    The gas chromatographic behavior of 32 carbamate pesticides was investigated using the Hall electrolytic conductivity detector. Relative retention indices were successfully determined for 24 carbamates on six different columns. Columns investigated included Ultra-Bond, 3% OV-101 on Ultra-Bond, 1% OV-17 on Ultra-Bond, 1% OV-210 on Ultra Bond, 1% Carbowax 20M on Ultra-Bond and 0.5% OV-210 + 0.65% OV-17 on Ultra-Bond. Chemical-ionization gas chromatography-mass spectrometry was used to verify that the carbamates were chromatographed intact. Chemical-ionization mass spectra are reported. Analytical procedures are demonstrated for the determination of carbamate residue in soil.