These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Blood flow in canine tibial diaphysis estimated by iodoantipyrine- 125 I washout.
    Author: Kelly PJ, Yipintsoi T, Bassingthwaighte JB.
    Journal: J Appl Physiol; 1971 Jul; 31(1):38-47. PubMed ID: 5556961.
    Abstract:
    Tibial bone blood flow was estimated in dogs by an indicator washout method using 125I-labeled 4-iodoantipyrine (I-Ap). The tibial cortical bone/blood partition coefficient, λ, of I-Ap was (mean ± sd) 0.150 ± 0.027 for 17 dogs. Tibial cortical bone blood flow (mean ± sd) was 0.0152 ± 0.003 ml/ml bone per min by the residue function technique of Zierler applied to 32 washout curves. Exponential analysis by the successive subtraction method gave the same mean value and, if the flow were considered to traverse two regions in parallel, suggested that 22% (sd, ±7.4) of the indicator traversed a high-flow region (mean flow, 0.265 ml/ml bone per min; sd, ±0.194) and the remainder had a mean flow of 0.0118 ml/ml bone per min (sd, ± 0.003).
    [Abstract] [Full Text] [Related] [New Search]