Search MEDLINE/PubMed


  • Title: Determination of 7-amino-flunitrazepam (Ro 20-1815) and 7-amino-desmethylflunitrazepam (Ro 5-4650) in plasma by high-performance liquid chromatography and fluorescence detection.
    Author: Sumirtapura YC, Aubert C, Coassolo P, Cano JP.
    Journal: J Chromatogr; 1982 Oct 08; 232(1):111-8. PubMed ID: 6128350.
    Abstract:
    A high-performance liquid chromatographic method for the simultaneous determination of 7-amino-flunitrazepam (Ro 20-1815) and 7-amino-desmethylflunitrazepam (Ro 5-4650) in plasma is described. After extraction with an organic solvent, the compounds and their internal standard (7-amino-methylclonazepam or Ro 5-3384) are derivatized with fluorescamine and chromatographed on a reversed-phase muBondapak C18 column using pH 8 buffer solution-acetonitrile (3:1) as mobile phase. The detection is performed by a fluorometer at excitation and emission wavelengths of 390 and 470 nm, respectively. The sensitivity limit is about 1 ng/ml of plasma for both 7-amino-flunitrazepam and 7-amino-desmethylflunitrazepam. The method has been applied to the determination of plasma levels of these substances during pharmacokinetic studies of flunitrazepam, desmethylflunitrazepam and 7-amino-flunitrazepam.