These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Routine amniotic fluid alpha-fetoprotein measurement in 34,000 pregnancies. Author: Crandall BF, Matsumoto M. Journal: Am J Obstet Gynecol; 1984 Aug 01; 149(7):744-7. PubMed ID: 6205588. Abstract: Of 34,000 initial amniotic fluid samples, 0.7% had an alpha-fetoprotein level greater than or equal to +3 SD above the mean. The risk of an open neural tube defect or other serious fetal abnormality was 60% when alpha-fetoprotein levels measured greater than or equal to +3 and 86% for levels greater than or equal to +5 SD. In this series there were 72 open neural tube defects, and all were identified. The true false positive rate was 0.9 per 10,000 cases screened.[Abstract] [Full Text] [Related] [New Search]