These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Normal appearance and reproducibility of liver-spleen studies with Tc-99m sulfur colloid and Tc-99m microalbumin colloid.
    Author: Klingensmith WC, Spitzer VM, Fritzberg AR, Kuni CC.
    Journal: J Nucl Med; 1983 Jan; 24(1):8-13. PubMed ID: 6217301.
    Abstract:
    In order to determine the normal biodistribution and reproducibility of Tc-99m sulfur colloid and Tc-99m microalbumin colloid, each of ten normal subjects was studied twice with each of the two agents. In overexposed delayed analog images of the anterior chest, some thyroid radioactivity was demonstrated in all of 20 microalbumin colloid studies and in none of 20 sulfur colloid studies; lung radioactivity was seen in 19 of 20 (95%) sulfur colloid studies and in none of the microalbumin colloid studies (both p less than 0.001). Delayed digital images showed that the sulfur colloid gave a higher lung-to-heart ratio, a higher lung-to-liver ratio, and a lower bone marrow-to-liver ratio compared with microalbumin colloid (all p less than 0.05). In general, reproducibility was poor for both agents. We conclude that while there are some differences between these two radiocolloids, the differences do not indicate a superiority of the newer Tc-99m microalbumin colloid over the established Tc-99m sulfur colloid for liver-spleen imaging.
    [Abstract] [Full Text] [Related] [New Search]