These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: [Pitfalls in the end-to-side anastomosis with the circular mechanical suture stapler]. Author: Adloff M, Ollier JC, Arnaud JP. Journal: Presse Med; 1983 May 14; 12(21):1359-61. PubMed ID: 6222319. Abstract: During end-to-side mechanical anastomosis with a circular stapler, an intestinal fold may be caught between the anvil and the loader resulting in obstruction, to a varying degree, of the efferent segment of the loop. This can be avoided by careful spreading of the bowel over the loader opposite the future anastomotic area.[Abstract] [Full Text] [Related] [New Search]